Product Details:
| Model | 62 MAX |
| Temperature Range | -30 to 500deg C |
| Distance To Spot | 10:1 |
| Mounting Type | FLUKE 62 MAX |
| Accuracy | ±1.5°C |
| Emissivity Setting | Fixed 0.95 |
| Laser Targeting | Single Laser |
| Brand | Fluke |
| Model Name/Number | 62 Max |
| Battery Life | 10 hours with Laser and Backlight On |
| Response Time | Less Than 500 ms (95% of reading) |
| Size/Dimension | 175 x 85 x 75 mm (6.88 x 3.34 x 2.95 in) |
| Weight | 255 g |
| Emissivity | 0.10 to 1.00 |
| Spectral Response | 8 to 14 microns |
| IP Rating | IP 54 per IEC 60529 |
Product Details:
| Model | 59 MAX+ |
| Temperature Range | -30 to 500 degC |
| Distance To Spot | 8:1 |
| Accuracy | ±2°C |
| Emissivity Setting | Adjustable |
| Laser Targeting | Dual Laser |
| Brand | Fluke |
| Model Name/Number | 59 Max+ |
| Response Time | Less Than 500 ms (95 % of reading) |
| Size/Dimension | (156 x 80 x 50) mm (6.14 x 3.15 x 2) inches |
| Weight | 220 g (7.76 oz) |
| Power | 1 AA IEC LR06 Battery |
| Repeatability | +/-0.8% of Reading or +/-1.0 degC,Whichever is Greater |
| Batter Life | 12 hours with Laser and Backlight On |
| Operating Humidity | 10% to 90% RH non-condensing @ 30 degC |
Product Details:
| Maximum DC Voltage | 600 V |
| Maximum AC Voltage | 300 V |
| Display Count | 2000 Count |
| Maximum DC Current | 400 mA |
| Maximum AC Current | 400 mA |
| Model Name/Number | 17B+ |
| Brand | Fluke |
| Temperature Range | Operating 0 to 40 degC; Storage -30 to 60 degC |
| Weight | 455 g |
| Display Type | LCD,4000 Counts,Updates 3/sec |
| Size | 183 mm x 91 mm x 49.5 mm |
| DC Voltage Accuracy | 0.5% + 3 |
| AC Voltage | 4.000 V,40.00 V,400.0 V,1000 V |
| AC Volts Resolution | 0.001 V,0.01 V,0.1 V,1 V |
| AC Volts Accuracy | 1.0% + 3 |
| DC Volts Range | 4.000 V,40.00 V,400.0 V,1000 V |
| DC Volts Resolution | 0.001 V,0.01 V,0.1 V,1 V |
| Altitude | Operating 2000 m; Storage 12,000 m |
| IP Rating | IP40 |
Product Details:
| Max AC Current | 1000A |
| AC Or DC Measurement | AC/DC |
| Current Type | AC/DC |
| Maximum Current (AC/DC) | 600 A |
| Measurement Type | True RMS |
| Max DC Voltage | 1000V |
| Maximum Voltage (AC/DC) | 600 V |
| Max AC Voltage | 1000V |
| Jaw Opening | 40 mm |
| Jaw Opening Size | 40mm |
| AC Current | 600.0 A |
| Model Name/Number | 303 |
| Brand | Fluke |
| Warranty | 2 Year |
| AC Voltage | 400/600 V |
| Features | Backlight |
| Safety Rating | CAT IV 600V |
| Power Source | AA Battery |
| Resistance | 4000 Ohm |
| AC Current Accuracy | 1.8% +- 5 |
| AC Voltage Accuracy | 1.5% +- 5 |
| Continuity | Less Than or Equals 70 Ohm |
| Size | 208 x 58.5 x 28 mm |
Product Details:
| Current Range | 0–400 A |
| Max AC Current | 600A |
| True RMS | Yes |
| Current Type | AC/DC |
| AC Or DC Measurement | AC/DC |
| Measurement Type | True RMS |
| Max DC Voltage | 600V |
| Max AC Voltage | 600V |
| Jaw Opening Size | 30mm |
| AC Current | 200 A |
| DC Current | 200 A |
| Model Name/Number | 362 |
| Brand | Fluke |
| Warranty | 2 Year |
| AC Voltage | 600 V |
| Weight | 196 g |
| Jaw opening | 18 mm |
| AC Current Resolution | 0.1 A |
| AC Current Accuracy | 2 % +/- 5 digits (45-65 Hz) |
| AC Voltage Resolution | 0.1 V |
| AC Voltage Accuracy | 1.5 % +/- 5 digits (45-400 Hz) |
| Size | 205 mm x 60 mm x 22 mm |
Product Details:
| Current Range | 0–1000 A |
| True RMS | Yes |
| AC Or DC Measurement | AC/DC |
| Jaw Opening | 37 mm |
| Max Voltage Range | 0–600 V |
| Safety Category | CAT IV 600 V |
| Brand | Fluke |
| Warranty | 1 year |
| Usage/Application | Industrial |
| AC Current Measurement | 600 A |
| AC and DC Voltage Measurement | 600 V |
| Temperature Measurement | From -10degree C to 400degree C (14degree F to 752degree F) |
Product Details:
| Application | Industrial |
| Model | 62 MAX |
| Temperature Range | -30–500°C |
| Distance To Spot | 10:1 |
| Emissivity | Adjustable |
| Emissivity Setting | Fixed 0.95 |
| Response Time | 500 ms |
| Laser Targeting | Dual Laser |
| Warranty | 12 Months |
| Brand | Fluke |
| Display Type | Backlit LCD |
| Color | Yellow |
| Country of Origin | Made in India |
| Accuracy | + or - 1 degree C |
| Measures Temperature | -40 to +80 degrees C |
Product Details:
| Model Series | 1577 |
| Max Dc Voltage | 1000 V |
| Max Ac Voltage | 1000 V |
| Warranty | 3 year |
| Maximum DC Current | 600 mA |
| Max Dc Current | 1000V |
| Maximum AC Current | 600 mA |
| True Rms | Yes |
| Model Name/Number | 1577 |
| Operating Temperature | -20deg C to +55deg C |
| Auto Ranging | Yes |
| Resistance Range | 50 M ohm Max |
| Brand | Fluke |
| Resistance Accuracy | +/-(1.2%+2) |
| Weight | 624 g |
| Size | 203 x 100 x 50 mm (With Holster) |
| DC Voltage Accuracy | +/-(0.2%+2) |
| Maximum DC Voltage | 1000 V |
| Maximum AC Voltage | 1000 V |
| Maximum DC Voltage Resolution | 0.001 V |
| AC Voltage Accuracy | +/-(2%+3) |
| Maximum AC Voltage Resolution | 0.1 mV |
| Minimum Test Current | 1 mA at 1k ohm /V |
| Storage Temperature | -40deg C to +60deg C |
| Humidity | 0% - 95% (10-30deg C) |
The Fluke 1587 and 1577 Insulation Multimeters combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
Whether you work on motors, generators, cables, or switch gear, the Fluke 1587/1577 Insulation Multimeters are ideally suited to help you with your tasks and at a cost that is far less than buying the two products.
Product Details:
| Current Range | 0–600 A |
| Max AC Current | 600A |
| True RMS | Yes |
| Current Type | AC/DC |
| AC Or DC Measurement | AC/DC |
| Measurement Type | True RMS |
| Max DC Voltage | 600V |
| Max AC Voltage | 600V |
| Jaw Opening Size | 30mm |
| AC Current | 999.9 A |
| Model Name/Number | 305 |
| Brand | Fluke |
| Warranty | 2 Year |
| AC Voltage | 400/600 V |
| Resistance | 4000 Ohm |
| AC Current Accuracy | 1.8% +- 5 |
| AC Voltage Accuracy | 1.5% +- 5 |
| Continuity | Less Than or Equals 70 Ohm |
| Size | 208 x 58.5 x 28 mm |
Product Details:
| Model Series | 15B+ |
| Maximum DC Voltage | 1000 V |
| Max Dc Voltage | 1000 V |
| Maximum AC Voltage | 500 V |
| Max Ac Voltage | 750 V |
| Warranty | 1 Year |
| Maximum DC Current | 20 A |
| Max Dc Current | 600 mA |
| Maximum AC Current | 20 A |
| Max Ac Current | 600 mA |
| True Rms | Yes |
| Brand | Fluke |
| Usage | Laboratory, Industrial |
| Display Count | 2000 Count |
| Safety Rating | CAT II 600 V |
| Additional Functions | Frequency |
| Country of Origin | Made in India |
| Frequency | 200 kHz and % duty cycle |
| DC Accuracy | 0.05% |
Product Details:
| Current Range | 0–1000 A |
| True RMS | Yes |
| AC Or DC Measurement | AC/DC |
| Jaw Opening | 34 mm |
| Max Voltage Range | 0–750 V |
| Safety Category | CAT III 600 V |
| Brand | Fluke |
| AC Voltage | 600.0 V |
| DC Current Range | 40.00 A, 600.0 A, 1000 A |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Unit |
| Model Series | FLUKE 114 |
| Maximum DC Voltage | 600 V |
| Max Dc Voltage | 1000 V |
| Maximum AC Voltage | 500 V |
| Max Ac Voltage | 1000 V |
| Warranty | 1 Year |
| Maximum DC Current | 600 mA |
| Max Dc Current | 600 mA |
| Maximum AC Current | 600 mA |
| Max Ac Current | 600 mA |
| True Rms | Yes |
| Brand | Fluke 114 |
| Type | Industrial Digital |
| DC Current | 400uA / 4000uA / 40mA / 400mA / 4A / 10A |
| AC Voltage | 400mV / 4V / 40V / 400V / 1000V |
Product Details:
| Model Series | 17B+ |
| Maximum DC Voltage | 600 V |
| Max Dc Voltage | 1000 V |
| Maximum AC Voltage | 1000 V |
| Max Ac Voltage | 500 V |
| Warranty | 1 Year |
| Maximum DC Current | 20 A |
| Max Dc Current | 600 mA |
| Maximum AC Current | 600 mA |
| Max Ac Current | 600 mA |
| True Rms | Yes |
| Brand | Fluke |
| Type | Industrial Digital |
| Weight | 455g |
| Temperature Operating | 0 degree C to 40 degree C |
| Size (HxWxL) | 183 x 91 x 49.5 mm |
Additional Information:
Product Details:
| Model Series | 179 |
| Maximum DC Voltage | 1000 V |
| Max Dc Voltage | 1000 V |
| Maximum AC Voltage | 1000 V |
| Max Ac Voltage | 1000 V |
| Maximum DC Current | 600 mA |
| Max Dc Current | 600 mA |
| Maximum AC Current | 600 mA |
| Max Ac Current | 1000V |
| True Rms | Yes |
| Brand | Fluke |
| Usage | Industrial |
| Condition | New |
| Max. Resolution | 0.1 mV, 0.01 mA |
| Operating Temperature | -10degree C to +50degree C |
| Weight | 420g |
Product Details:
| Model Series | 101 |
| Maximum DC Voltage | 600 V |
| Max Dc Voltage | 600 V |
| Maximum AC Voltage | 600 V |
| Max Ac Voltage | 600 V |
| Warranty | 1 Year |
| Maximum DC Current | 400 mA |
| Max Dc Current | 600 mA |
| Maximum AC Current | 400 mA |
| Max Ac Current | 600 mA |
| True Rms | Yes |
| Model Name/Number | 101 |
| Battery | Two AAA |
| Brand | Fluke |
| Weight | 160 g |
| Size | 130 mm x 65 mm x 27mm |
| AC Voltage | 600mV,6V,60V,600V |
| AC Voltage Resolution | 0.1 mV,0.001V,0.01V,0.1V |
| AC Voltage Accuracy | 3.0% +/- 3 Digit,1.0% +/-3 Digit |
| Capacitance | 50.00 nF,500.0 nF,5.000 mu F,50.00 mu F,100.0 mu F |
| Duty Cycle | 0.1% to 99.9% |
| CAT Rating | CAT III 600 V |
Product Details:
| Current Range | 0–600 A |
| Brand | Fluke |
| True RMS | Yes |
| AC Or DC Measurement | AC/DC |
| Jaw Opening | 34 mm |
| Max Voltage Range | 0–750 V |
| Safety Category | CAT III 1000 V |
| AC Current | 400.0 A |
| Model Name/Number | 302+ |
| Warranty | 2 Year |
| AC Voltage | 400/600 V |
| Resistance | 4000 Ohm |
| AC Current Accuracy | 1.8% +- 5 |
| AC Voltage Accuracy | 1.5% +- 5 |
| Continuity | Less Than or Equals 70 Ohm |
| Size | 208 x 58.5 x 28 mm |
Product Details:
| Type | Digital |
| Maximum DC Voltage | 600 V |
| Max Dc Voltage | 750 V |
| Maximum AC Voltage | 300 V |
| Max Ac Voltage | 300 V |
| Maximum DC Current | 400 mA |
| Max Dc Current | 200 mA |
| Display Count | 1999 Count |
| True Rms | Yes |
| Model Name/Number | 15B Plus |
| Resistance Range | 400.0 Ohm |
| Brand | Fluke |
| Resistance Accuracy | 0.5% + 3 |
| Temperature Range | Operating 0 to 40 degC; Storage -30 to 60 degC |
| Weight | 455 g |
| Display Type | LCD,4000 Counts,Updates 3/sec |
| DC Voltage Accuracy | 0.5% + 3 |
| AC Voltage | 4.000 V |
| AC Voltage Resolution | 0.001 V |
| AC Voltage Accuracy | 1.0% + 3 |
| Resistance Resolution | 0.1 Ohm |
| Battery Type | 2 AA,NEDA 15 A,IEC LR6 |
Product Details:
| Current Range | 0–600 A |
| Brand | Fluke |
| True RMS | FLUKE 319 |
| AC Or DC Measurement | AC/DC |
| Jaw Opening | 319 |
| Max Voltage Range | 0–1000 V |
| Safety Category | CAT III 600 V |
| AC Current | 40.00 A |
| DC Current | 40.00 A |
| Model Name/Number | 319 |
| AC Current Resolution | 0.01 A |
| AC Current Accuracy | 1.6 % +/- 6 digit (50-60 Hz) |
| DC Current Resolution | 0.01 A |
| DC Current Accuracy | 1.6 % +/- 6 digit [40 A] |
| Continuity | Less Than or Equals 30 Ohm |
Product Details:
| Application | Industrial |
| Model | 59 MAX |
| Temperature Range | -30 degC to 350 degC |
| Distance To Spot | FLUKE 59MAX |
| Contact Type | Contact + IR |
| Accuracy | ±2°C |
| Emissivity Setting | Adjustable |
| Brand | Fluke |
| Laser Targeting | Single Laser |
| Model Name/Number | 59 Max |
| Response Time | Less Than 500 ms (95% of reading) |
| Size/Dimension | (156 x 80 x 50) mm (6.14 x 3.15 x 2) inches |
| Weight | 220 g (7.76 oz) |
| Power | 1 AA IEC LR06 Battery |
| Emissivity | 0.10 to 1.00 |
| Spectral Response | 8 to 14 mu m |
| Batter Life | 12 hours With Laser and Backlight On |
| Operating Humidity | 10% to 90% RH non-condensing @ 30 degC |
| Operating Altitude | 2000 meters Above Mean Sea Level |
Product Details:
| Model Series | FLUKE 115 |
| Type | Digital |
| Maximum DC Voltage | 750 V |
| Max Dc Voltage | 1000 V |
| Maximum AC Voltage | 600 V |
| Max Ac Voltage | 750 V |
| Maximum DC Current | 400 mA |
| Max Dc Current | 400 mA |
| Maximum AC Current | 600 mA |
| True Rms | Yes |
| Model Name/Number | 115 |
| Display Count | 1999 Count |
| Operating Temperature | -10 to + 50 degC |
| Battery | 9 volt Alkaline, NEDA 1604A/ IEC 6LR61 |
| Brand | Fluke |
| Display Type | Digital 6,000 Counts, Updates 4/sec |
| DC Voltage Accuracy | 0.5 % + 2 |
| Bar Graph | 33 Segments, Updates 32/sec |
| Storage Temperature | -40 to + 60 degC |
| DC Voltage Range | 6.000 V |
| DC Voltage Resolution | 0.001 V |
| Continuity Range | 600 Ohm |
| Continuity Resolution | 1 ohm |
Product Details:
| Current Range | 0–1000 A |
| Brand | Fluke |
| True RMS | Yes |
| AC Or DC Measurement | AC/DC |
| Jaw Opening | 55 mm |
| Max Voltage Range | 0–1000 V |
| Safety Category | CAT IV 600 V |
| AC Current | 999.9 A |
| DC Current | 999.9 A |
| Model Name/Number | 376 |
| Data Logging | Yes |
| Bluetooth | Yes |
| Resistance | 60,000 Ohm |
| AC Current Resolution | 0.1 A |
| AC Current Accuracy | 2 % +/- 5 digits |
| DC Current Resolution | 0.1 A |
| DC Current Accuracy | 2 % +/- 5 digits |
| Resistance Resolution | 0.1 Ohm |
| Resistance Accuracy | 1 % +/- 5 digits |
Product Details:
| Model Series | 87V |
| Max Dc Voltage | 1000 V |
| Max Ac Voltage | 1000 V |
| Max Dc Current | 600 mA |
| Maximum AC Current | 600 mA |
| Max Ac Current | 400 mA |
| True Rms | Yes |
| Brand | Fluke 87V |
| Operating Temperature | -20 to + 55 deg C |
| Resistance Accuracy | +/-(0.2% + 1) |
| Frequency Accuracy | +/-(0.005% + 1) |
| DC Current Accuracy | +/-(0.2% + 2) |
| Weight | 355 g,624 g - with holster |
| AC Current Accuracy | +/-(0.7% + 2) True RMS |
| Size | 201 x 98 x 52 mm (With Holster) |
| DC Voltage Accuracy | +/-(0.05% + 1) |
| Humidity | 0% - 90% (0 - 35 deg C) |
| Maximum DC Voltage | 1000 V |
| Maximum AC Voltage | 1000 V |
| Maximum DC Current | 10 A (20 A for 30 seconds Maximum) |
| Frequency | 87V |
| Maximum DC Voltage Resolution | 10 mu V |
| Maximum Resistance | 50 M ohm |
| Maximum Resistance Resolution | 0.1 ohm |
| Maximum Frequency | 200 kHz |
| Storage Temperature | -40 to + 60 deg C |
Product Details:
| Current Range | 0–600 A |
| Display Type | Digital |
| AC Or DC Measurement | AC/DC |
| Jaw Opening | 30 mm |
| Max Voltage Range | 0–750 V |
| True RMS | Yes |
| DC Voltage | 400/600 V |
| AC Current | 999.9 A |
| Brand | Fluke |
| Warranty | 2 Year |
| AC Voltage | 400/600 V |
| Size | 208 x 58.5 x 28 mm |
| Temperature | 0 ~ 40 deg C |
Additional Information:
Product Details:
| Minimum Order Quantity | 1 Unit |
| Model | Fluke 424D |
| Measuring Range | 0.05 to 80 m |
| Accuracy | ±2 mm |
| Laser Class | Class 2M |
| Usage/Application | Industrial |
| Functions | Min Max, Volume |
| Power Source | 424D |
| IP Rating | IP40 |
| Brand | Leica, Fluke |
| Country of Origin | Made in India |
| Higher Accuracy | +-1 mm (0.04 in) |
| Measures up to | 100 m (330 ft) |
Additional Information:
Product Details:
| Measurement Type | Insulation |
| Fluke Series | 1507 |
| Resistance Range | Up to 200 MΩ |
| Brand | Fluke |
| Test Voltage | Up to 5 kV |
| Display Type | Digital |
| Interface | Bluetooth |
| Model Name/Number | 1507 |
| Operating Temperature | -20 to 55deg C |
| Overload Protection | 600 V rms or DC (Voltage Measurement) |
| Size | 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in) |
| Weight | 550 g (1.2 lb) |
| Input Impedance | 3 M ohm (nominal), Less Than100 pF (Voltage Measurement) |
| Insulation Measurement Range | 0.01 M ohm to 10 G ohm |
| Insulation Test Voltage | 50 V, 100 V, 250 V, 500 V, 1000 V |
| Insulation Test Voltage Accuracy | + 20%, - 0% |
| Storage Temperature | -40 to 60deg C |
| Vibration | Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 Instrument |
The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications.
Take advantage of the 1507 full feature set to easily and quickly perform advanced insulation resistance testing. Its handy size and light weight make it easy to pack and use. Additional features, like the remote probe, save both time and money especially when performing repetitive tests. And its reasonable price and rugged reliability make it an excellent value.